Product Center

Municipal tap water reverse osmosis membrane TW-8040

Category: Municipal tap water reverse osmosis membrane

The TW (TapWater) series membrane elements are designed for desalination of water sources—including surface water, groundwater, tap water, and municipal water—with a salt content of approximately 2000 ppm or less. They are primarily used in a wide range of industries, such as the production of purified water of various scales, boiler feedwater, food processing, and pharmaceutical manufacturing.

Product Introduction

◎ Product Introduction and Application Fields

  The TW (TapWater) series membrane elements are designed for desalination of water sources—including surface water, groundwater, tap water, and municipal water—with a salt content of approximately 2000 ppm or less. They are primarily used in a wide range of industries, such as the production of purified water of various scales, boiler feedwater, food processing, and pharmaceutical manufacturing.

 

◎ Model Specifications and Parameters

Product Model Effective membrane area ft² (㎡) Application test pressure psi (MPa) Water production GPD (m³/d) Stable Desalination Rate / %
TW-8040-HR 400 (37) 150(1.03) 10500 (39.5) 99.3
TW-8040-HF 400 (37) 150(1.03) 11,000 (41.6) 99.0
TW-8040-FR 365 (33.9) 150(1.03) 10500 (39.5) 99.5

 

  a. The water production rate and desalination rate are based on the following test conditions: softened tap water at 1500 ppm, water temperature of 25℃, pH of 7.5, a single-element recovery rate of 15%, and the rated operating pressure specified above.

  b. The water production of a single component may vary within a range of ±15%.

 

◎ Operating Limits

 

Operating limit Membrane element type Polyamide composite membrane
Maximum operating temperature 45℃
Maximum working pressure 600 psi (4.14 MPa)
Maximum Inflow Rate 85 GPM (19 m³/h)
Minimum brine flow rate 15 GPM (3.4 m³/h)
Continuous operating pH range 3-10
pH range for chemical cleaning 2-12
Maximum Silt Density Index (SDI) for Inlet Water 15 5
Maximum Inlet Turbidity/NTU 1
Maximum residual chlorine concentration in influent / (mg/L) 0.1
Maximum pressure drop for a single component 15 (0.1) psi (MPa)

Keywords: Municipal tap water reverse osmosis membrane TW-8040